Washington State University reactor pulse exceeded 830 degrees Celsius limit

Initial calculations estimated a peak of about 870 degrees Celsius, below the 1,000-degree limit for standard fuel and 1,150-degree limit for 30/20 low enriched uranium fuel.

Image: Washington State University Reactor — C. Corey Hines, Public domain, Wikimedia Commons

Key facts

  • Reactor scrammed and was shut down at the time of notification
  • Estimated pulse reactivity was $2.50; the operator had been preparing a $1.85 insertion
  • The operator used control element 4 data instead of control element 3 data

A pulse at Washington State University’s modified Training, Research, Isotopes, General Atomics (TRIGA) reactor exceeded the 830 degrees Celsius fuel-temperature limit for pulsing, the NRC reported on November 13, 2026. The licensee reported that the reactor scrammed and was shut down at the time of notification.

A senior reactor operator had been preparing a $1.85 pulse reactivity insertion to collect data for maximum reactivity calculations. The operator used control element 4 data instead of the correct control element 3 data, setting the cylinder height at 9.13 inches rather than the 7.25 inches required for the pulse. The pulse rod was ejected at 9.13 inches; its estimated reactivity insertion was $2.50.

Initial calculations put peak fuel temperature at about 870 degrees Celsius, above the operating limit but below the stated safety limits of 1,000 degrees Celsius for standard fuel and 1,150 degrees Celsius for 30/20 low enriched uranium fuel. The licensee reported the apparent Technical Specifications violation to the NRC as a reportable occurrence; a follow-up report is due in 10 days.

1 source

More on US Nuclear Regulatory Commission

Report an error